Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 1781
SNMP Introduction
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
67.23
8.
Set the previous release
file to be the backup
release that the device
will install and run if the
device fails to boot
successfully with the
new release file.
Include the path.
bckpPath
1.3.6.1.4.1.207.8.4.4.4.500.2.3.2
Set:
<backup-filename>
e.g.:
flash:/release.rel
9.
Check the version of
backup release file.
bckpVersion
1.3.6.1.4.1.207.8.4.4.4.500.2.3.1
Read:
10.
If necessary, copy a
configuration file to the
device (
), or
save the current running
configuration to a file in
the root directory of
flash. To save the
running configuration,
specify the filename, but
not a device or path.
See
.
or
runCnfgSaveAs
1.3.6.1.4.1.207.8.4.4.4.500.3.1.1
Set:
<filename.cfg>
e.g.:
myconfig.cfg
11.
Check and if necessary
set the file the device
will use for
configuration when it
restarts.
Include the full path.
bootCnfgPath
1.3.6.1.4.1.207.8.4.4.4.500.3.2.1
Read/set:
<filename.cfg>
e.g.:
flash:/myconfig.cfg
12.
Check that a boot
configuration file
matching the boot
configuration path
exists.
bootCnfgExists 1.3.6.1.4.1.207.8.4.4.4.500.3.2.2
Read:
TRUE (1)
or
FALSE (2)
13.
Check that the default
configuration file
flash:/default.cfg exists.
dfltCnfgExists
1.3.6.1.4.1.207.8.4.4.4.500.3.3.2
Read:
TRUE (1)
or
FALSE (2)
14.
Restart the device.
restartDevice
1.3.6.1.4.1.207.8.4.4.4.500.1
1
Table 67-6: Procedure for upgrading to a new software version and boot configuration(cont.)
Do this ...
By reading or
setting this MIB
object ...
Whose object ID is ...
To this value ...