Timezone – Brocade Mobility RFS Controller CLI Reference Guide (Supporting software release 5.5.0.0 and later) User Manual
Page 841
![background image](/manuals/361696/841/background.png)
828
Brocade Mobility RFS Controller CLI Reference Guide
53-1003098-01
7
Example
rfs7000-37FABE(config-device-00-04-96-4A-A7-08)#sensor-server 1 ip
172.16.10.7
rfs7000-37FABE(config-device-00-04-96-4A-A7-08)#show context
br71xx 00-04-96-4A-A7-08
use profile default-br71xx
use rf-domain default
hostname TechPubAP7131
floor 5thfloor
layout-coordinates 1.0 2.0
license AP aplicenseley@1234 aplicensekey@123
rsa-key ssh rsa-key1
location Block3B
no contact
country-code us
sensor-server 1 ip 172.16.10.7
channel-list 2.4GHz 1,2
override-wlan test vlan-pool 8
mac-name 00-04-96-4A-A7-08 5.4TestAP
neighbor-info-interval 50
rfs7000-37FABE(config-device-00-04-96-4A-A7-08)#
Related Commands:
timezone
Configures device’s timezone
Supported in the following platforms:
•
Access Points — Brocade Mobility 650 Access Point, Brocade Mobility 6511 Access Point,
Brocade Mobility 1220 Access Point, Brocade Mobility 71XX Access Point, Brocade
Mobility 1240 Access Point
•
Wireless Controllers — Brocade Mobility RFS4000, Brocade Mobility RFS6000, Brocade
Mobility RFS7000
•
Service Platforms — Brocade Mobility RFS9510
Syntax:
timezone
Parameters
ip
Configures sensor server’s IP address
•
port
[443|8443|<1-65535>]
Optional. Configures the port. The options are:
•
443 – The default port used by the AirDefense server
•
8443 – The default port used by advanced WIPS
•
<1-65535> – Manually sets the port number of the advanced WIPS/AirDefense server
Removes configured sensor server