Shutdown, Sniffer-redirect – Brocade Mobility RFS Controller CLI Reference Guide (Supporting software release 5.5.0.0 and later) User Manual
Page 740
Brocade Mobility RFS Controller CLI Reference Guide
727
53-1003098-01
7
rf-mode sensor
placement outdoor
mesh client
rts-threshold 100
off-channel-scan channel-list 2.4GHz 1
guard-interval long
aggregation ampdu tx-only
rifs tx-only
aeroscout forward
ekahau forward ip 172.16.10.1 port 3
non-unicast tx-rate bss 1 dynamic-all
non-unicast tx-rate bss 2 highest-basic
non-unicast tx-rate bss 3 highest-basic
non-unicast tx-rate bss 4 highest-basic
non-unicast tx-rate bss 5 highest-basic
--More--
rfs7000-37FABE(config-profile-71xxTestProfile-if-radio1)#
Related Commands:
shutdown
interface-config-radio-instance
Terminates or shuts down selected radio interface
Supported in the following platforms:
•
Access Points — Brocade Mobility 650 Access Point, Brocade Mobility 6511 Access Point,
Brocade Mobility 1220 Access Point, Brocade Mobility 71XX Access Point, Brocade
Mobility 1240 Access Point
Syntax:
shutdown
Parameters
None
Example
rfs7000-37FABE(config-profile-71xxTestProfile-if-radio1)##shutdown
rfs7000-37FABE(config-profile-71xxTestProfile-if-radio1)#
Related Commands:
sniffer-redirect
interface-config-radio-instance
Captures and redirects packets to an IP address running a packet capture/analysis tool
Supported in the following platforms:
Resets a radio’s RTS threshold to its default
Enables a disabled radio interface