use firewall-policy default
enforce-version adoption major
enforce-version cluster full
service pm sys-restart
router ospf
rfs7000-37FABE(config-profile-default-rfs7000)#
Related Commands:
environmental-sensor
Configures the environmental sensor settings
A Brocade Mobility 1240 Access Point sensor module is a USB environmental sensor extension to a
Brocade Mobility 1240 Access Point model access point. It provides a variety of sensing
mechanisms, allowing the monitoring and reporting of the Brocade Mobility 1240 Access Point's
radio coverage area.
Supported in the following platforms:
•
Access Points — Brocade Mobility 1240 Access Point
Syntax:
environmental-sensor [humidity|light|motion|polling-interval|temperature]
environmental-sensor [humidity|motion|polling-interval <1-100>|temperature]
environmental-sensor light {holdtime|radio-shutdown|threshold}
environmental-sensor light {holdtime <2-201>|radio-shutdown
[all|radio-1|radio-2]}
environmental-sensor light {threshold [high <100-10000>|low <0-1000>]}
Parameters
environmental-sensor [humidity|motion|polling-interval <1-100>|temperature]
Disables or reverts settings to their default
environmental-sensor
Configures environmental sensor settings on this profile
humidity
Enables (turns on) humidity sensors. This setting is enabled by default.
motion
Enables (turns on) motion sensors.This setting is enabled by default.
polling-interval
<1-100>
Configures polling interval, in seconds, on all sensors. This is the interval after which the sensor module polls its
environment to assess the various parameters, such as light intensity.
•
<1-100> – Specify a value from 1 - 100 seconds. The default is 11 seconds.
temperature