Brocade Mobility RFS Controller CLI Reference Guide (Supporting software release 5.5.0.0 and later) User Manual
Page 1015
Brocade Mobility RFS Controller CLI Reference Guide
1005
53-1003098-01
14
storm-control [arp|broadcast|multicast|unicast] level <1-1000000> [fe <1-4>|
ge <1-8>|port-channel <1-8>|up1|wlan
storm-control [arp|bcast|multicast|unicast] log
[<0-7>|alerts|critical|debugging|
emergencies|errors|informational|none|notifications|warnings]
Example
rfs7000-37FABE(config-fw-policy-test)#storm-control arp log warning
rfs7000-37FABE(config-fw-policy-test)#storm-control broadcast level 20000 ge 4
rfs7000-37FABE(config-fw-policy-test)#show context
firewall-policy test
ip dos fraggle drop-only
no ip dos tcp-sequence-past-window
ip dos tcp-max-incomplete high 600
arp
Configures storm control for ARP packets
broadcast
Configures storm control for broadcast packets
multicast
Configures storm control for multicast packets
unicast
Configures storm control for unicast packets
level <1-1000000>
Configures the allowed number of packets received per second before storm control begins
•
<1-1000000> – Sets the number of packets received per second
fe <1-4>
Sets the FastEthernet port for storm control from 1 - 4
ge <1-8>
Sets the GigabitEthernet port for storm control from 1 - 8
port-channel <1-8>
Sets the port channel for storm control from 1- 8
up1
Sets the uplink interface
wlan
Configures the WLAN
•
arp
Configures storm control for ARP packets
broadcast
Configures storm control for broadcast packets
multicast
Configures storm control for multicast packets
unicast
Configures storm control for unicast packets
log
Configures the storm control log level for storm control events
<0-7>
Sets the numeric logging level from 0 - 7
alerts
Numerical severity 1. Indicates a condition where immediate action is required
critical
Numerical severity 2. Indicates a critical condition
debugging
Numerical severity 7. Debugging messages
emergencies
Numerical severity 0. System is unusable
errors
Numerical severity 3. Indicates an error condition
informational
Numerical severity 6. Indicates a informational condition
none
Disables storm control logging
notification
Numerical severity 5. Indicates a normal but significant condition
warnings