27
hysteresis min-threshold -65
hysteresis root-sel-snr-delta 12
rfs4000-229D58(config-profile-testAP71XX-meshpoint-test)#
Related Commands:
monitor
Enables monitoring of critical resource and primary port links. It also configures the action taken in
case a critical resource goes down or a primary port link is lost.
Supported in the following platforms:
•
Access Points — Brocade Mobility 1220 Access Point, Brocade Mobility 71XX Access Point,
Brocade Mobility 1240 Access Point
•
Access Points (as root APs only) — Brocade Mobility 650 Access Point
Syntax:
monitor [critical-resource|primary-port-link-loss]
monitor [critical-resource|primary-port-link-loss] action no-root
Parameters
monitor [critical-resource|primary-port-link-loss] action no-root
Example
rfs7000-37FABE(config-profile-AP71XXTestProfile-meshpoint-test)#monitor
critical-resource action no-root
rfs7000-37FABE(config-profile-AP71XXTestProfile-meshpoint-test)#show context
meshpoint-device test
name test
monitor critical-resource action no-root
rfs7000-37FABE(config-profile-AP71XXTestProfile-meshpoint-test)#
Related Commands:
path-method
Removes the configured path selection SNR hysteresis values
critical-resource
Enables critical resource down event monitoring
primary-port-link-loss
Enables primary port link loss event monitoring
action
The following are common to all of the above:
•
action – Sets the action taken if a critical resource goes down or if a primary port link is lost
•
no-root – Changes the meshpoint to be non root (this is the action taken in case any of the
above mentioned two events occur)