Brocade Mobility RFS Controller CLI Reference Guide (Supporting software release 5.5.0.0 and later) User Manual
Page 653
![background image](/manuals/361696/653/background.png)
640
Brocade Mobility RFS Controller CLI Reference Guide
53-1003098-01
7
environmental-sensor light {holdtime <2-201>|radio-shutdown
[all|radio-1|radio-2]}
environmental-sensor light {threshold [high <100-10000>|low <0-1000>]}
Example
rfs4000-229D58(config-profile-testBrocade Mobility
RFS4000)#environmental-sensor humidity
rfs4000-229D58(config-profile-testBrocade Mobility
RFS4000)#environmental-sensor polling-interval 60
rfs4000-229D58(config-profile-testBrocade Mobility
RFS4000)#environmental-sensor light radio-shutdown all
rfs4000-229D58(config-profile-testBrocade Mobility
RFS4000)#environmental-sensor light threshold high 300
rfs4000-229D58(config-profile-testBrocade Mobility
RFS4000)#environmental-sensor light threshold low 100
rfs4000-229D58(config-profile-testBrocade Mobility RFS4000)#show context
profile rfs4000 testBrocade Mobility RFS4000
bridge vlan 1
tunnel-over-level2
ip igmp snooping
ip igmp snooping querier
environmental-sensor polling-interval 60
environmental-sensor light threshold high 300
environmental-sensor light threshold low 100
environmental-sensor
Configures environmental sensor settings on this profile
light
Enables (turns on) light sensors and specifies its settings
When enabled, the sensor module polls the environment to determine the light intensity. Based on the reading,
the system determines whether the Brocade Mobility 1240 Access Point’s deployment location has lights on or
off. Light intensity also helps determine whether the access point’s deployment location is currently populated
with clients.
holdtime <2-201>
Optional. Configures a holdtime, in seconds, for the light sensor
•
<2-201> – Specify a value from 2 - 201 seconds.
radio-shutdown
[all|radio1|radio2]
Optional. Shuts down the sensor’s radios
•
all – Shuts down all radios
•
radio1 – Shuts down radio 1
•
radio2 – Shuts down radio 2
Brocade Mobility 1240 Access Point’s using this profile have their radios shut down, when the radio’s power falls
below the specified threshold.
environmental-sensor
Configures environmental sensor settings on this profile
light
Enables (turns on) light sensors and specifies its settings
threshold
Optional. Configures the upper and lower thresholds for the amount of light in the environment
high <100-10000>
Specifies the upper threshold from 100 - 10000 lumens. This value determines whether lighting is on in the
AP8132’s deployment location. The default is 500 lux.
The light sensor triggers an event if the amount of light exceeds the specified value.
low <0-1000>
Specifies the lower threshold from 0 - 1000 lumens. This value determines whether lighting is off in the Brocade
Mobility 1240 Access Point’s deployment location. The default is 100 lux.
The light sensor triggers an event if the amount of light drops below the specified value.