Smart-ocs-monitoring, Smart-ocs-monitorin g – Brocade Mobility RFS Controller CLI Reference Guide (Supporting software release 5.5.0.0 and later) User Manual
Page 1148
1140
Brocade Mobility RFS Controller CLI Reference Guide
53-1003098-01
20
•
Wireless Controllers — Brocade Mobility RFS4000, Brocade Mobility RFS6000, Brocade
Mobility RFS7000
•
Service Platforms — Brocade Mobility RFS9510
Syntax:
sensitivity [custom|high|low|medium]
Parameters
sensitivity [custom|high|low|medium]
Usage Guidelines:
To enable the power and channel setting parameters, set sensitivity to custom or medium.
To enable the monitoring and scanning parameters, set sensitivity to custom.
To enable the neighbor recovery, interference and coverage hole recovery parameters, set
sensitivity to custom.
Example
rfs7000-37FABE(config-smart-rf-policy-test)#sensitivity high
rfs7000-37FABE(config-smart-rf-policy-test)#show context
smart-rf-policy test
area test channel-list 2.4GHz 1,2,3
group-by floor
sensitivity high
channel-list 2.4GHz 1,12
channel-width 5GHz auto
smart-ocs-monitoring frequency 5GHz 3
smart-ocs-monitoring frequency 2.4GHz 3
smart-ocs-monitoring sample-count 5GHz 3
smart-ocs-monitoring sample-count 2.4GHz 3
--More--
rfs7000-37FABE(config-smart-rf-policy-test)#
smart-ocs-monitoring
Applies smart Off Channel Scanning (OCS) instead of dedicated detectors
Supported in the following platforms:
•
Access Points — Brocade Mobility 650 Access Point, Brocade Mobility 6511 Access Point,
Brocade Mobility 1220 Access Point, Brocade Mobility 71XX Access Point, Brocade
Mobility 1240 Access Point
sensitivity
Configures Smart RF sensitivity levels. The options available are: custom, high, low, and medium.
custom
Enables custom interference recovery, coverage hole recovery, and neighbor recovery as additional Smart
RF options
high
High sensitivity
low
Low sensitivity
medium