beautypg.com

Brocade Mobility RFS Controller CLI Reference Guide (Supporting software release 5.5.0.0 and later) User Manual

Page 794

background image

Brocade Mobility RFS Controller CLI Reference Guide

781

53-1003098-01

7

Access Points — Brocade Mobility 650 Access Point, Brocade Mobility 6511 Access Point,
Brocade Mobility 1220 Access Point, Brocade Mobility 71XX Access Point, Brocade
Mobility 1240 Access Point

Wireless Controllers — Brocade Mobility RFS4000, Brocade Mobility RFS6000, Brocade
Mobility RFS7000

Service Platforms — Brocade Mobility RFS9510

Syntax:

noc update-interval [<5-3600>|auto]

Parameters

noc update-interval [<5-3600>|auto]

Example

rfs7000-37FABE(config-profile-default-rfs7000)#noc update-interval 25

rfs7000-37FABE(config-profile-default-rfs7000)#show context

profile rfs7000 default-rfs7000

mint link ip 1.2.3.4

mint level 1 area-id 88

bridge vlan 1

bridging-mode isolated-tunnel

ip igmp snooping

ip igmp snooping querier

...................................................

interface pppoe1

use firewall-policy default

misconfiguration-recovery-time 65

noc update-interval 25

service pm sys-restart

router ospf

rfs7000-37FABE(config-profile-default-rfs7000)#

Related Commands:

ntp

Profile Config Commands

Configures the Network Time Protocol (NTP) server settings

Supported in the following platforms:

Access Points — Brocade Mobility 650 Access Point, Brocade Mobility 6511 Access Point,
Brocade Mobility 1220 Access Point, Brocade Mobility 71XX Access Point, Brocade
Mobility 1240 Access Point

update-interval
[<5-3600>|auto]

Configures NOC statistics update interval

<5-3600> – Specify the update interval from 5 - 3600 seconds.

auto – The NOC statistics update interval is automatically adjusted by the wireless controller or service
platform based on load

no

Resets NOC related parameters