Example

rfs7000-37FABE(config-management-policy-test)#snmp-server community snmp1 ro

rfs7000-37FABE(config-management-policy-test)#snmp-server host 172.16.10.23

v3 162

rfs7000-37FABE(config-management-policy-test)#commit

rfs7000-37FABE(config-management-policy-test)#snmp-server user snmpmanager v3

auth md5 motorola1123

rfs7000-37FABE(config-management-policy-test)#show context

management-policy test

no http server

https server

ftp username superuser password 1

626b4033263d6d2ae4e79c48cdfcccb60fd4c77a8da9e365060597a6d6570ec2 rootdir dir

no ssh

snmp-server community snmp1 ro

snmp-server user snmpmanager v3 encrypted des auth md5 0 motorola1123

snmp-server host 172.16.10.23 v3 162

aaa-login radius external

aaa-login radius policy test

idle-session-timeout 0

restrict-access host 172.16.10.2 log all

rfs7000-37FABE(config-management-policy-test)#

Related Commands:

ssh

management-policy

Enables Secure Shell (SSH) for this management policy

SSH, like Telnet, provides a command line interface to a remote host. SSH transmissions are
encrypted and authenticated, increasing the security of transmission. SSH access is disabled by
default.

Supported in the following platforms:

Access Points — Brocade Mobility 650 Access Point, Brocade Mobility 6511 Access Point,
Brocade Mobility 1220 Access Point, Brocade Mobility 71XX Access Point, Brocade
Mobility 1240 Access Point

Wireless Controllers — Brocade Mobility RFS4000, Brocade Mobility RFS6000, Brocade
Mobility RFS7000

Service Platforms — Brocade Mobility RFS9510

Syntax:

ssh {login-grace-time <60-300>|port <1-65535>}

Parameters

no

Disables or resets the SNMP server settings