Filter-ageout, Frame-type – Brocade Mobility RFS Controller CLI Reference Guide (Supporting software release 5.5.0.0 and later) User Manual
Page 1170
![background image](/manuals/361696/1170/background.png)
1162
Brocade Mobility RFS Controller CLI Reference Guide
53-1003098-01
21
filter-ageout
Configures the filter ageout interval in seconds. This is the duration a client, triggering a WIPS
event, is excluded from RF Domain manager radio association.
Supported in the following platforms:
•
Access Points — Brocade Mobility 650 Access Point, Brocade Mobility 6511 Access Point,
Brocade Mobility 1220 Access Point, Brocade Mobility 71XX Access Point, Brocade
Mobility 1240 Access Point
•
Wireless Controllers — Brocade Mobility RFS4000, Brocade Mobility RFS6000, Brocade
Mobility RFS7000
•
Service Platforms — Brocade Mobility RFS9510
Syntax:
filter-ageout <1-86400>
Parameters
filter-ageout <1-86400>
Example
rfs7000-37FABE(config-test-signature-test)#filter-ageout 8
rfs7000-37FABE(config-test-signature-test)#show context
signature test
bssid 11-22-33-44-55-66
dst-mac 55-66-77-88-99-00
filter-ageout 8
rfs7000-37FABE(config-test-signature-test)#
Related Commands:
frame-type
Configures the frame type used for matching with this WIPS policy signature
Supported in the following platforms:
•
Access Points — Brocade Mobility 650 Access Point, Brocade Mobility 6511 Access Point,
Brocade Mobility 1220 Access Point, Brocade Mobility 71XX Access Point, Brocade
Mobility 1240 Access Point
•
Wireless Controllers — Brocade Mobility RFS4000, Brocade Mobility RFS6000, Brocade
Mobility RFS7000
•
Service Platforms — Brocade Mobility RFS9510
Syntax:
filter-ageout
<1-86400>
Configures the filter ageout interval from 1 - 86400 seconds
Removes the configured filter ageout interval