If no SMART RF policy is mapped, the radio selects a random channel

If the radio is a dedicated sensor, it stops termination on that channel if a neighboring access point
detect radar. The access point attempts to come back to its original channel (statically configured
or selected by Smart RF) after the channel evacuation period has expired.

Change this behavior using the

dfs-rehome

command from the controller or service platform CLI.

This keeps the radio on the newly selected channel and prevents the radio from coming back to the
original channel, even after the channel evacuation period.

NOTE

Perform RF planning to ensure overlapping coverage exists at a deployment site, for Smart RF to be
a viable network performance tool. Smart RF can only provide recovery when access points are
deployed appropriately. Smart RF is not a solution, it is a temporary measure. You need to determine
the root cause of RF deterioration and fix it. Smart RF history/events can assist in trouble shooting.

Use the (config) instance to configure Smart RF Policy related configuration commands. To
navigate to the Smart RF policy instance, use the following commands:

(config)#smart-rf-policy

rfs7000-37FABE(config)#smart-rf-policy test

rfs7000-37FABE(config-smart-rf-policy-test)#?

Smart RF Mode commands:

area Specify channel list/ power for an area

assignable-power Specify the assignable power during power-assignment

channel-list Select channel list for smart-rf

channel-width Select channel width for smart-rf

coverage-hole-recovery Recover from coverage hole

enable Enable this smart-rf policy

group-by Configure grouping parameters

interference-recovery Recover issues due to excessive noise and

interference

neighbor-recovery Recover issues due to faulty neighbor radios

no Negate a command or set its defaults

sensitivity Configure smart-rf sensitivity (Modifies various

other smart-rf configuration items)

smart-ocs-monitoring Smart off channel scanning

clrscr Clears the display screen

commit Commit all changes made in this session

end End current mode and change to EXEC mode

exit End current mode and down to previous mode

help Description of the interactive help system

revert Revert changes

service Service Commands

show Show running system information

write Write running configuration to memory or terminal

rfs7000-37FABE(config-smart-rf-policy-test)#

smart-rf-policy

SMART-RF-POLICY