Changing cimom server credentials, Testing cimom server credentials, Changing cimom – Brocade Network Advisor SAN + IP User Manual v12.3.0 User Manual
Page 759: Server credentials
Brocade Network Advisor SAN + IP User Manual
687
53-1003155-01
Port commissioning
14
Changing CIMOM server credentials
You can edit the CIMOM server credentials for one or more CIMOM servers at the same time.
1. Select Configure > Port Commissioning > Setup.
The Port Commissioning Setup dialog box displays (
Figure 281
).
2. Select one or more CIMOM servers from the Systems List and click Change Credentials.
The Edit Credentials dialog box displays. If you selected one CIMOM server, the credentials for
the selected server display in the dialog box. If you selected more than one CIMOM server, the
credential fields are empty.
3. (Optional) Enter a user identifier for the CIMOM server in the User ID field.
The user identifier cannot be over 128 characters.
4. (Optional) Enter a password in the Password field.
The password cannot be over 512 characters.
5. Click OK to close the Edit Credentials dialog box.
In the Port Commissioning Setup dialog box, the status of the selected CIMOM server rows
displays “Credentials Updated”.
To validate the credentials, refer to
“Testing CIMOM server credentials”
6. Click OK to close the Port Commissioning Setup dialog box.
Testing CIMOM server credentials
You should validate the CIMOM server credentials before you decommission or recommission
ports. During the decommission or recommission of an F_Port, the Management application
validates the CIMOM server credentials.
1. Select a device and select Configure > Port Commissioning > Setup.
The Port Commissioning Setup dialog box displays (
Figure 281
).
2. Select one or more CIMOM servers from the Systems List and click Test.
The status of the selected CIMOM server rows display “Testing” in the Systems List. When
testing is complete, the CIMOM server connectivity status displays. Valid status options
include:
•
OK — CIMOM server contact successful with current credentials.
•
Not Contacted Yet — CIMOM servers configured, connectivity not tested yet.
•
Credentials Updated — Credentials changed, connectivity not tested yet.
•
Credentials Failed — CIMOM server contact failed with current credentials.
•
Not Reachable — CIMOM server not reachable.
•
Wrong Namespace — CIMOM server namespace is incorrect.
3. Click OK to close the Port Commissioning Setup dialog box.
When the test is complete, an application event displays in the Master Log detailing success or
failure.