Brocade Network Advisor SAN + IP User Manual v12.3.0 User Manual
Page 2498
2426
Brocade Network Advisor SAN + IP User Manual
53-1003155-01
Database tables and fields
I
TIME_IN_SECONDS
Time, in seconds, at which the record was inserted in
seconds.
int
COLLECTOR_ID
DB ID of the collector object used for collection.
int
TABLE 377
SNMP_EXPR_DATA_30MIN
Field
Definition
Format
Size
ID
Primary key autogenerated ID
int
EXPRESSION_ID
DB ID of the expression object used for collection
int
TARGET_TYPE
Target/Source type can be device:0 or
interface/ports:1'
smallint
TARGET_ID
DB Id of the target which can be device or interface
int
VALUE
Value collected by the engine'
double
precision
TIME_IN_SECONDS
Time at which collection occured in seconds
int
COLLECTOR_ID
DB Id of the collector object used for collection
int
TABLE 378
SNMP_EXPRESSION
Field
Definition
Format
Size
EXPRESSION_ID Primary key column.
serial
NAME
Name of the expression.
varchar
64
DESCRIPTION
Description of the expression.
varchar
512
EQUATION
Equation of the expression.
varchar
1024
UNIT
Unit that is used for displaying the chart.
varchar
64
IS_TRANSIENT
Explicitly identified whether expressions is used for
Real time collector or not. A transient expression will
not be allowed for user editing.
numeric
(1,0)
TABLE 379
SNMP_PROFILE
Field
Definition
Format
Size
NAME*
A text string representing a set of SNMP agent
profile. When created, one or more virtual switches
could refer to this profile for its SNMP credentials
unless a unique set of SNMP credentials has been
defined in SNMP_CREDENTIAL.
varchar
256
PORT_NUMBER
Port number of the SNMP agent on the switch for
get and set requests
smallint
RETRY_COUNT
Number of times to retry if get/set request to the
SNMP agent times out. Default value is 3.
smallint
TIMEOUT
Timeout value in seconds before for a get/set
request to the SNMP agent. Default value is 5.
smallint
TABLE 376
SNMP_EXPR_DATA_1DAY (Continued)
Field
Definition
Format
Size