Firmware management

14

If you have your FTP server configured to use an external FTP server, the Firmware to Download
column is empty.

6. (External FTP, SCP, or SFTP server) If you configured an external FTP, SCP, or SFTP server,

choose from one of the following options in the External FTP/SCP/SFTP Server area:

Select the FTP server option to download from the external FTP server and configure the
following on the FTP server:

a. Create a user name and password.

b. Select the Shared folders link and set the firmware location as the home directory and

select all check boxes under the Files and Directories attributes. Continue with

step 7

.

Select the SCP Server option to download from the external SCP server. Continue with

step 7

.

NOTE

The Management application only supports WinSSHD as the third-party Windows external
SCP server. Firmware upgrade and downgrade through WinSSHD is only supported on
devices running Fabric OS 6.0 or later.

Select the SFTP Server option to download from the external SFTP server. Continue with

step 7

.

NOTE

The Management application only supports WinSSHD as the third-party Windows external
SFTP server. Firmware upgrade and downgrade through WinSSHD is only supported on
devices running Fabric OS 7.0 or later.

7. (External FTP, SCP, or SFTP server) If you configured an external server, enter the path to the

firmware directory in the Firmware Directory field.

A confirmation message displays. Click Yes on the confirmation message.

This field does not display if the external server is installed on the same machine as the
Management application and occupies port 21.

8. To download the firmware to the selected switches one at a time, select the Serial download

check box.

Use the Up and Down buttons to determine the order in which the firmware is downloaded to
the switches. If firmware download fails on one switch, all other switches in the queue will be
skipped.

If the Serial download check box is cleared, the download occurs in parallel on the switches
(up to 20 at a time).

9. To overwrite the current firmware, even if the selected version is the same as the version

currently running on the switch, click the Overwrite current firmwares check box.

10. Click Download.

While the firmware is downloaded to the device, the Status column displays the current
download status. Once firmware download is complete, the Message column displays whether
the download was a success or failure.