802.1ag Connectivity Fault Management

37

VPLS Manager (requires the IP - MPLS – VLL prvilege with read-write or read-only permission)

VLL Manager (requires the IP - MPLS – VPLS prvilege with read-write or read-only permission)

VLAN Manager (requires the VLAN Manager prvilege with read-write or read-only permission)

NOTE

802.1ag CFM is only supported on IronWare Ethernet Routers devices running firmware release 5.2
or later.

NOTE

You cannot configure an 802.1ag CFM on a maintenance end point (MEP) configured with dual
tagged VLANs.

Use linktrace messages to identify fault locations by sending a query to maintenance end points
(MEP) or maintenance intermediate points (MIP) along the service path of the domain.

To send a link trace message to a specific MEP or MIP in the domain, complete the following steps.

1. Choose one of the following options:

From the VPLS Manager dialog box, Views tab, choose one of the following options:

Select a device from the VPLS Peer Status/VPLS Name/VCID list and click 802.1ag
CFM.

Select the Peer Topology tab and right-click a device in the topology and select
802.1ag CFM.

From the VLL Manager dialog box, Views tab, select an instance from the VLL Instances
table and click 802.1ag CFM.

From the VLAN Manager dialog box - VLAN View or Product View, select a VLAN from list
and click 802.1ag CFM.

The Configure 802.1ag CFM dialog box displays the product that contains the selected MEP,
the domain, the maintenance association, and the port number of the selected MEP.

2. Select the MEP for which you want to send a link trace message to a specific maintenance end

point (MEP) or maintenance intermediate point (MIP) in the domain in the Maintenance End
Points (MEP) table.

3. Click Linktrace.

The 802.1ag CFM Linktrace dialog box displays.

4. Select the MEP for which you want to send a linktrace message to a specific maintenance end

point (MEP) or maintenance intermediate point (MIP) in the domain in the Maintenance End
Points (MEP) table.

5. Click Linktrace.

The 802.1ag CFM Linktrace dialog box displays.

6. Select one of the following destination options:

MEP ID — Select this option to send the linktrace message to a MEP and enter the MEP ID
in the field. THe MEP ID value can be 1 through 8191.

MIP — Select this option to send the linktrace message to a MIP and enter the MAC
address for the MIP.

7. Enter a timeout value in seconds (from 1 through 30) in the Timeout field.