53-1003155-01

802.1ag Connectivity Fault Management

37

Save to running and startup then reboot — Select to update the running configuration,
save the deployment configuration to the product’s flash memory, and reboot the product.
Selecting this option is the equivalent to entering a write memory and a reload command
on the product CLI.

13. Click OK on the Deploy to Products dialog box.

The Deployment Status dialog box displays.

While deployment is in progress, you can do the following:

Click Abort to stop deployment of the entire configuration.

NOTE

The abort action does not stop the tasks that have already started.

Click Close to close the Deployment Status dialog box.

NOTE

Closing the Deployment Status dialog box does not stop deployment of the configuration.

After deployment is complete, you can select an entry in the Deployment Status list to display
details about the deployment in the Status Details field.

14. Click Close on the Deployment Status dialog box.

The Configure 802.1ag CFM dialog box displays with the updated details in the Maintenance
Association Details table.

15. Click Close on the Configure 802.1ag CFM dialog box.

Viewing the MEPs in a maintenance association

You can access 802.1ag CFM from the following features:

VPLS Manager (requires the IP - MPLS – VLL prvilege with read-write or read-only permission)

VLL Manager (requires the IP - MPLS – VPLS prvilege with read-write or read-only permission)

VLAN Manager (requires the VLAN Manager prvilege with read-write or read-only permission)

NOTE

802.1ag CFM is only supported on IronWare Ethernet Routers devices running firmware release 5.2
or later.

NOTE

You cannot configure an 802.1ag CFM on a maintenance end point (MEP) configured with dual
tagged VLANs.

To view the MEPs in a maintenance association, complete the following steps.

1. Choose one of the following options:

-

From the VPLS Manager dialog box, Views tab, choose one of the following options:

Select a device from the VPLS Peer Status/VPLS Name/VCID list and click 802.1ag
CFM.