beautypg.com

Top port link failures monitor – Brocade Network Advisor SAN + IP User Manual v12.3.0 User Manual

Page 362

background image

290

Brocade Network Advisor SAN + IP User Manual

53-1003155-01

Dashboard customization

7

Top Port Link Failures monitor

The Top Port Link Failures monitor displays the top ports with link failures in a table.

The Top Port Link Failures monitor includes the following data:

Widget title — The name of the widget.

View Details icon — Click to launch the Detailed View page.

Widget summary — The product count for each status (worst to best) displays underneath the
widget title.

Top value — The highest value in the table.

Port — The port affected by this monitor. Click to launch the Port Page (refer to

“Port summary

view”

on page 325). When you launch the Port page, the detailed view closes.

Connected_Port (where Connected_Port is Connected Port, Initiator, or Target) — Displays the
address of the port:

RX Link Failures/sec — The number (error rate) receive link failure errors per second for the
duration specified in the monitor.

RX Link Failures — The number (error count) of receive link failure errors.

TX Link Failures/sec — The number (error rate) of transmit link failure errors for the duration
specified in the monitor.

TX Link Failures — The number (error count) of transmit link failure errors.

Viewing additional details for the Top Port Link Failures monitor

1. Click the View Details icon.

A more detailed widget displays which includes the following data:

Scope — The scope configured for the dashboard.

Port — The port affected by this monitor. Click to launch the Port Page (refer to

“Port

summary view”

on page 325). When you launch the Port page, the detailed view closes.

Connected_Port (where Connected_Port is Connected Port, Initiator, or Target) — Displays
the address of the port:

RX Link Failures/sec — The number (error rate) receive link failure errors per second for
the duration specified in the monitor.

RX Link Failures — The number (error count) of receive link failure errors.

TX Link Failures/sec — The number (error rate) of transmit link failure errors for the
duration specified in the monitor.

TX Link Failures — The number (error count) of transmit link failure errors.

Product — The product affected by this monitor.

Type — The type of port (for example, U-Port).

Identifier — The port identifier.

Port Number — The port number.

State — The port state (for example, Enabled).

Status — The port status (for example, Up).

2. Click the close (X) button.