Cascaded FICON fabric merge
30
•
Checks the primary and secondary fabrics for any merge issues.
•
Configures High Integrity Fabric Configuration (HIFC) on the seed switch of the primary and
secondary fabric.
-
SCC policy will be created or modified to limit connectivity to switches from both fabrics.
-
Configures Fabric-Wide Consistency Policy (FWCP) on both fabrics.
-
FWCP is configured in tolerant mode for SCC for an Fibre Channel Routing (FCR) fabric.
•
Enables Port-Based Routing (PBR) on all switches in the secondary fabric if all the switches in
the primary fabric are found to be enabled for PBR. Note that a mixed policy of
Exchanged-Based Routing (EBR), Device-Based Routing (DBR) and PBR cannot be enabled on
a fabric.
•
Enables Exchange-Based Routing (EBR) on all switches in the secondary fabric if all switches in
the primary fabric are enabled for EBR. Note that EBR requires that switches operate at 8 Gbps
or greater with Fabric OS 6.4 or later. If all the EBR-enabled switches in the primary fabric are
found to meet these requirements and a switch in the secondary fabric does not meet these
requirements, an error message displays. Note that a mixed policy of EBR and PBR cannot be
enabled on a fabric.
•
Enables Device-Based Routing (DBR) on all switches in the secondary fabric if all switches in
the primary fabric are enabled for DBR. Note that DBR requires that switches operate at 8
Gbps or greater with Fabric OS 7.1 or later. If all the DBR-enabled switches in the primary fabric
are found to meet these requirements and a switch in the secondary fabric does not meet
these requirements, an error message displays. Note that a mixed policy of PBR, EBR, and DBR
cannot be enabled on a fabric.
•
(Optional) Turns on FICON Management Server (FMS) mode on all switches. If some switches
already have FMS mode enabled, it is re-enabled.
Consider the following information when enabling FMS mode.
-
If switches are running Fabric OS 7.0 and later, FMS will not be enabled unless the
switches have an active CUP license.
-
If switches are running Fabric OS earlier than version 7.0 and do not have a CUP license,
after successful configuration, you can access the Port Connectivity (Allow/Prohibit)
matrix, but the host system cannot communicate with the FICON Management Server
unless you install a CUP license. If a CUP license is later installed on these switches, then
FMS mode must be re-enabled on these switches.
-
For logical fabrics running Fabric OS v7.1 or later, you can enable FMS mode when logical
switches are configured to allow XISL use.
•
(Optional) Configures long distance settings on selected ports of primary and secondary
fabrics (requires an Extended Fabric license).
NOTE
If the distance between the merged fabrics is 10 km or greater, you must configure the
connection as a long distance connection.
Note that the merge wizard does not enable primary fabric switches for DLS, In-Order Delivery
(IOD), insistent domain ID flag (IDID), and Advanced Performance Tuning (APT).
•
In-Order Delivery (IOD) will be enabled on all switches in the secondary fabric.
•
Dynamic Load Sharing (DLS) will be enabled on switches in the secondary fabric that are
operating at 8 Gbps or greater and are running Fabric OS 6.3 or later.