Adding a configuration policy manager
47
a. Select one or more of the following checks in the Available Checks list to include them in
the configuration policy manager:
For more information about these checks and fixes for rule violations, refer to
router configuration policy managers”
NOTE
The Check for HTTPS (secure HTTP) configuration checks are not supported on Network
OS products and the following IronWare products: Ethernet Core routers, Ethernet Carrier
routers, Ethernet Edge router, and Data Center switch, as well as the Brocade 6650
Ethernet switch, router, and Layer 3 router.
NOTE
The Check for Secure SSH (secure Telnet) configuration checks are not supported on the
following IronWare products: Application products running 12.3.X or earlier and the
Brocade 6910 Ethernet switch.
•
Select the Check if the product is configured to send events to this server to
determine if the Management application server is registered as an SNMP recipient
and syslog recipient.
•
Select the Check for redundant connections to neighboring switches (SAN only) check
box to determine if there are at least the minimum number of configured ISLs
between each switch pair.
•
Select the Check for HTTPS (secure HTTP) configuration check box to check each
target to see if HTTPS is active for device data transmission.
•
Select the Check if the product is configured to send Upload Failure Data Capture to
an FTP server (SAN only) check box to determine the following configurations:
– Upload Failure Data Capture is enabled on the selected switches.
– A configured FTP Server is accessible.
– You have write permission to the directory.
•
Select the Check for SSH (secure Telnet) configuration check box to check each target
to see if SSH is enabled for device data transmission.
•
Select the Check for SNMPv3 (secure SNMP) configuration check box to check each
target to see if SNMPv3 is active for device data transmission and SNMPv1 and
SNMPv2 are not configured.
•
Select the Check for VLAN configurations match for each connection (IP only) check
box to determine the consistency of VLAN configurations for each connection on the
selected IP devices.
b. Click the right arrow button to move the selected checks to the Selected Checks list.
c. If you selected the Check for redundant connections to neighboring switches (SAN only)
check box, enter the minimum number of connections allowed between a switch pair in
the Minimum Connections field.
The default recommended is 2. Valid values are from 2 through 512.
d. If you selected the Check for MAPS action parameter dialog check box, you must select the
necessary actions that need to be verified in the MAPs action parameter dialog.