Database tables and fields
I
SERIAL_NUMBER
provides the serial number of the sensor, requested
by SMIA and values filled in by Switch Asset Collector
will be available only from FOS 6.4 switches and
above
varchar
64
VERSION
provides the version of the sensor, requested by
SMIA and values filled in by Switch Asset Collector
will be available only from FOS 6.4 switches and
above
varchar
32
CREATION_TIME
provides the record creation time, standard columns
for Management application and values filled in by
Switch Asset Collector
timestamp
LAST_UPDATE_TIME
provides the record last updated time, standard
columns for Management application and values
filled in by Switch Asset Collector
timestamp
FRU_TYPE
provides the type of the sensor, requested by SMIA
and values filled in by Switch Asset Collector will be
available only from FOS 6.4 switches and above. The
values represents FAN,PS, SLOT etc. The default
value is -1.
int
UNIT_NUMBER
provides the unit number of the sensor, requested by
SMIA and values filled in by Switch Asset Collector
will be available only from FOS 6.4 switches and
above . This the gives the index of the unit. For SLOT
FRU, this will be slot number. For FAN fru, this will be
fan number. The default value is -1.
int
STATE
provides the state of the sensor, requested by SMIA
and values filled in by Switch Asset Collector will be
available only from FOS 6.4 switches and above.
This gives the value whether the FRU is On or Off .
The default value is -1.
int
TABLE 352
SFLOW_CHECKPOINT
Field
Definition
Format
Size
TABLE_TO_DROP
Staging child tables previously checkpointed
(indicating that their aggregation was completed).
varchar
40
TABLE 353
SFLOW_HOUR_SUMMARY
Field
Definition
Format
Size
SLNUM
This column is used to store a counter value to
identify the total row count.
bigserial
TIME_IN_SECONDS Data
collection time in seconds.
int
DEVICE_ID
ID of the product which sends the sflow traffic.
int
IN_UNIT
Unit number of the incoming traffic interface. Default
value is 0.
smallint
IN_SLOT
Slot number of the incoming traffic interface.
smallint
IN_PORT
Port number of the incoming traffic interface.
smallint
TABLE 351
SENSOR
(Continued)
Field
Definition
Format
Size