Examples of circuit failover in groups – Brocade Network Advisor SAN + IP User Manual v12.3.0 User Manual
Page 1295
![background image](/manuals/361717/1295/background.png)
Brocade Network Advisor SAN + IP User Manual
1223
53-1003155-01
FCIP trunking
27
Examples of circuit failover in groups
Tables
Table 116
through
Table 118
provide examples of how failover occurs on circuits with
different bandwidths configured in failover groups.
Table 116
illustrates circuit failover in a tunnel with two failover groups, each with two circuits. All
data through the tunnel is initially load balanced over Circuits 1 and 2. The following occurs during
circuit failover:
•
If circuit 1 fails, circuit 3 becomes active and data is load balanced over circuit 2 and 3.
•
If circuit 2 fails, circuit 4 becomes active and data is load balanced over circuit 1 and 4.
•
If both circuit 1 and 2 fail, circuit 3 and.4 become active and data is load balanced over both
circuits.
Table 117
illustrates circuit failover in a tunnel with one failover group containing three circuits, In
this case, failover occurs as if circuits are not part of a failover group. Circuit 2 and 3, both with
metric 1, become active only after circuit 1 with metric 0 fails.
Table 118
illustrates circuit failover in a tunnel with circuits in failover groups and circuits that are
not part of failover groups. In this configuration, all data is initially load balanced over circuit.1,
circuit 2, and circuit 3 (when they are all active). The following occurs during circuit failover:
•
If circuit1 fails, circuit 4 becomes active and data is load balanced over circuit 2, circuit 3, and
circuit 4.
Reason: Circuit 1 fails over to circuit 4 (both are in failover group 1) and circuit 3 is active with
500Mb bandwidth.
•
If circuit 2 fails, data is load balanced over circuit 1 and circuit 3, and no other circuit becomes
active.
Reason: Circuit 1 and 3 are the only active circuits since circuit 4 and 5 only become active
when circuits 3 or 1 fail.
TABLE 116
Tunnel with two failover groups with two circuits
Circuits in tunnel
Failover group ID
Circuit bandwidth
In use for tunnel data
Circuit 1
Metric 0
1
500Mb
If active, yes.
Circuit 2
Metric 0
2
1000Mb
If active, yes.
Circuit 3
Metric 1
1
500Mb
Only when circuit 1
fails.
Circuit 4
Metric 1
2
1000Mb
Only when circuit 2
fails.
TABLE 117
Tunnel with one failover groups with three circuits
Circuits in tunnel
Failover group ID
Circuit bandwidth
In use for tunnel data
Circuit 1
Metric 0
1
1000Mb
If active, yes.
Circuit 2
Metric 1
1
500Mb
Only when circuit 1
fails.
Circuit 3
Metric 1
1
500Mb
Only when circuit 1
fails.