beautypg.com

Dell Emulex Family of Adapters User Manual

Page 958

background image

Emulex Drivers Version 10.2 for Linux User Manual

P010081-01A Rev. A

4. Troubleshooting

Log Messages

958

could not create sysfs group

The creation of the “flash_fw” entry under the
/sys/class/net/eth failed. The driver is fully
functional but you cannot install later firmware
versions on the adapter.

Error

Could not enable VLAN

Promiscuous mode

Firmware command failed to enable VLAN
promiscuous mode.

Error

Could not get crc from flash,

not flashing redboot

The driver could not get enough information from
the adapter to decide whether or not Redboot (the
primary boot program) should be flashed. The
driver skips updating this section. This is a very
unlikely error.

Error

Could not set PCI DMA Mask

The operating system call to set the DMA mask
failed.

Error

created

RSS queue(s) and

1 default RX queue

This is an information message reporting how many
receive rings with RSS capability were created. In
addition, a default receive ring is created to
receive non-IP traffic.

Information

enabled MSI-x vector(s)

for NIC

The number of MSI-x vectors enabled for the NIC
function.

Information

Error detected in the card

ERR: sliport status

ERR: sliport error1

ERR: sliport error2

There is an SLIPORT error detected in the adapter,
followed by status and error messages.

Error

Exhausted VLAN HW filters

When VLAN filters are exhausted, the driver
enables VLAN promiscuous mode.

Warning

Firmware flashed

successfully

This is an informational message that the firmware
on the adapter has been updated.

Information

Firmware load error

Updating the adapter with new firmware failed.
Usually this message is accompanied by a detailed
message on the failure.

Error

Firmware load not allowed

(interface is down)

Flashing firmware failed, as the status of the
interface is down.

Error

Firmware on card is old ,

IRQs may not work.

Please upgrade firmware to

version >= 4.0

On the OCx10xxx chip, firmware is too old to
support IRQs. To support IRQs on this adapter, the
firmware version should be at least version 4.0.x.x
or later.

Note: Before performing a firmware update, driver

installation is required. See “Installing and
Uninstalling” on page 816.

Error

Flashing firmware file

This is an informational message that the firmware
in the adapter is being updated with the firmware
image in the file indicated.

Information

Table 4-5 Ethernet Driver Log Messages of Type (Continued)

Ethernet Log Message

Description

Type