Dell Emulex Family of Adapters User Manual
Page 881

Emulex Drivers Version 10.2 for Linux User Manual
P010081-01A Rev. A
4. Troubleshooting
Log Messages
881
0115: Unknown ELS command
Received an unsupported ELS command from a remote N_Port.
Data:
None
Severity: Error
Log:
Always
Action:
Check the remote N_Port for a potential issue.
0125: FDISC Failed (x%x). Fabric out of resources
The fabric rejected an FDISC because the switch cannot support additional virtual ports.
Data:
lsRjtError
Severity: Error
Log:
Always
Action:
Reconfigure the switch to support more NPIV logins. If this issue persists, contact
Technical Support.
0126: FDISC failed ulpStatus ulpWord4
Data:
lsRjtError
Severity: Error
Log:
Always
Action:
Reconfigure the switch to support more NPIV logins. If this issue persists, contact
Technical Support.
0127: ELS timeout
An ELS IOCB command was posted to a ring and did not complete within ULP timeout seconds.
Data:
(1) elscmd (2) remote_id (3) ulpcommand (4) ulpIoTag
Severity: Error
Log:
Always
Action:
If no ELS command is going through the adapter, reboot the system; If the issue persists,
contact Technical Support.
0133: PLOGI: no memory for reg_login
Memory allocation error.
Data:
(1) nlp_DID (2) nlp_state (3) nlp_flag (4) nlp_rpi
Severity: Error
Log:
LOG_ELS
Action:
Memory allocation error. Check system resources. Unload unused modules.
0134: PLOGI cannot issue reg_login
The ELS PLOGI mailbox command has failed.
Data:
(1) nlp_DID (2) nlp_state (3) nlp_flag (4) nlp_rpi
Severity: Error
Log:
LOG_ELS
Action:
Check the port and switch configuration.
0135: cannot format reg_login
Could not allocate an RPI or DMA buffer for the mailbox command.
Data:
(1) nlp_DID (2) nlp_state (3) nlp_flag (4) nlp_rpi
Severity: Error
Log:
LOG_ELS
Action:
None required.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)