P010081-01A Rev. A

4. Troubleshooting

Log Messages

881

0115: Unknown ELS command received from NPORT

Received an unsupported ELS command from a remote N_Port.

Data:

None

Severity: Error
Log:

Always

Action:

Check the remote N_Port for a potential issue.

0125: FDISC Failed (x%x). Fabric out of resources

The fabric rejected an FDISC because the switch cannot support additional virtual ports.

Data:

lsRjtError

Severity: Error
Log:

Always

Action:

Reconfigure the switch to support more NPIV logins. If this issue persists, contact
Technical Support.

0126: FDISC failed ulpStatus ulpWord4

Data:

lsRjtError

Severity: Error
Log:

Always

Action:

Reconfigure the switch to support more NPIV logins. If this issue persists, contact
Technical Support.

0127: ELS timeout

An ELS IOCB command was posted to a ring and did not complete within ULP timeout seconds.

Data:

(1) elscmd (2) remote_id (3) ulpcommand (4) ulpIoTag

Severity: Error
Log:

Always

Action:

If no ELS command is going through the adapter, reboot the system; If the issue persists,
contact Technical Support.

0133: PLOGI: no memory for reg_login

Memory allocation error.

Data:

(1) nlp_DID (2) nlp_state (3) nlp_flag (4) nlp_rpi

Severity: Error
Log:

LOG_ELS

Action:

Memory allocation error. Check system resources. Unload unused modules.

0134: PLOGI cannot issue reg_login

The ELS PLOGI mailbox command has failed.

Data:

(1) nlp_DID (2) nlp_state (3) nlp_flag (4) nlp_rpi

Severity: Error
Log:

LOG_ELS

Action:

Check the port and switch configuration.

0135: cannot format reg_login

Could not allocate an RPI or DMA buffer for the mailbox command.

Data:

(1) nlp_DID (2) nlp_state (3) nlp_flag (4) nlp_rpi

Severity: Error
Log:

LOG_ELS

Action:

None required.

Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)