Dell Emulex Family of Adapters User Manual
Page 436

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
5. CLI Client Command Descriptions
Profile Management Commands
436
Examples
4 Partitions/Port
>hbacmd CMSetBW 00-00-c9-12-34-56 15,50 30,100 40,100 15,50
>hbacmd CMGetParams 00-00-c9-12-34-56
Active mode: NPAR
Configured mode: NPAR
Available modes: NPAR
Func# Type MAC Address Min BW Max BW
----- ----- ----------------- ------ ------
0 NIC 00-00-c9-12-34-56 15 50
1 iSCSI 00-00-c9-12-34-57 30 100
2 FCoE 00-00-c9-12-34-58 40 100
3 NIC 00-00-c9-12-34-59 15 50
4 Partitions/Port - 3rd, 4th Partition Protocol=None
>hbacmd CMSetBW 00-00-c9-12-34-56 50,100 60,100 0,0 0,0
>hbacmd CMGetParams 00-00-c9-12-34-56
Active mode: NPAR
Configured mode: NPAR
Available modes: NPAR
Func# Type MAC Address Min BW Max BW
----- ----- ----------------- ------ ------
0 NIC 00-00-c9-12-34-56 40 100
1 iSCSI 00-00-c9-12-34-57 60 100
2 None 00-00-c9-12-34-58 0 0
3 None 00-00-c9-12-34-59 0 0
8 Partitions/Port - 2 Port Card, NParEP Mode Enabled, Last Channel MinBandwith=0
>hbacmd cmsetbw 00-00-c9-12-34-56 10,100, 30,100 10,100, 10,100,
10,100, 10,100, 10,100, 10,100
>hbacmd cmgetparams 00-00-c9-12-34-56
Active mode: NPAR
Configured mode: NPAR
Available modes: NPAR
Func# Type MAC Address Min BW Max BW