Dcb tab field definitions, Figure 6-34 – Dell Emulex Family of Adapters User Manual
Page 1239

OneCommand Manager for VMware vCenter Version 10.2 User Manual
P010089-01A Rev. A
6. Managing Adapters and Ports
iSCSI Port
1239
Figure 6-34 DCB Tab (iSCSI Adapter Port Selected)
DCB Tab Field Definitions
DCBX State – The current DCBX state (enabled or disabled).
LLDP Transmit State – DCBX uses LLDP to exchange parameters between two
link peers. For the DCBX protocol to operate correctly, both LLDP Rx and Tx
must be enabled. If either Rx or Tx is disabled, DCBX is disabled.
LLDP Receive State – DCBX uses LLDP to exchange parameters between two
link peers. For the DCBX protocol to operate correctly, both LLDP Rx and Tx
must be enabled. If either Rx or Tx is disabled, DCBX is disabled.
PFC Properties Area
Note: PFC is not supported on all the iSCSI adapter ports.
State – Enabled means that flow control in both directions (Tx and Rx) is
enabled.
Active Priorities – Lists the priorities with PFC set to Enabled.
Sync'd – If yes, the PFC priorities have been set by the peer. This parameter
cannot be set.
Error – The error state. This capability indicates whether an error has occurred
during the configuration exchange with the peer. Error is also set to YES when
the Compatible method for the capability fails.
iSCSI Properties Area
State – The iSCSI state. It can be Enabled or Disabled.
Active Priority – The current active priority assigned for FCoE.