Profile management commands, Getadapterportconfig – Dell Emulex Family of Adapters User Manual
Page 415

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
5. CLI Client Command Descriptions
Profile Management Commands
415
Profile Management Commands
GetAdapterPortConfig
This command displays the active and reboot adapter port configurations of an
OCe14000-series adapter. This includes the total number of ports, the maximum
number of FCoE and iSCSI functions that can be defined, and whether mixed mode and
concurrent mode storage are supported by the adapter. Additionally, it shows if RoCE
is supported on the adapter and if a reboot is currently required to activate the new
configuration.
The number of functions displayed per port depends upon the current configuration of
the adapter, such as mixed or concurrent storage mode, multichannel, or NPar.
Notes
In the information displayed for the reboot configuration, each of the ports
displays the pN parameter name in parenthesis. The pN parameter is used in
the SetAdapterPortConfig command to change the port's protocol assignments.
This is helpful when the physical port numbering on the adapter does not start
at 0.
Depending upon the presence of ARI on a host, this command may show more
partitions per port than are actually running on the host.
For multichannel and Dell NPar configurations, this command only displays
the port protocol assignments. For the entire multichannel configuration use the
“CMGetParams” command on page 342.
RoCE is only available on Windows operating systems.
Supported By
Linux, Solaris, VMware ESXi, and Windows
Syntax
GetAdapterPortConfig
Parameters
Examples
Mixed Mode-4PortAdapter
>hbacmd getadapterportconfig 00-00-c9-12-34-56
Number of Ports : 4
Maximum FCoE Functions : 4
Maximum iSCSI Functions : 4
Mixed Mode I/O Allowed : Yes
MAC
MAC address of any iSCSI, or NIC, NIC + RoCE function on the adapter.
WWPN