beautypg.com

Dell Emulex Family of Adapters User Manual

Page 956

background image

Emulex Drivers Version 10.2 for Linux User Manual

P010081-01A Rev. A

4. Troubleshooting

Log Messages

956

2718: Clear Virtual Link Received for VPI tag

A Clear virtual link was received from the Fabric for this VPI.

Data:

None

Severity: Error
Log:

LOG_DISCOVERY

Action:

None required.

2719: Invalid response length: tgt lun cmnd rsplen

The response length for this FCP command is not supported.

Data:

None

Severity: Error
Log:

LOG_FCP

Action:

None required.

2721: ndlp null for oxid %x SID %x\n, icmd->ulpContext,

dfchba->ct_ctx[tag].SID);

The Node value for this SID is not in the node list.

Data:

None

Severity: Warning
Log:

LOG_ELS

Action:

None required.

2726: READ_FCF_RECORD Indicates empty FCF table

The driver requested the firmware provide a list of FCF entries to connect to and the firmware
responded that the FCF table is empty.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)