Dell Emulex Family of Adapters User Manual
Page 420

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
5. CLI Client Command Descriptions
Profile Management Commands
420
10.2 and later. If these conditions are not met, although you may configure all sixteen
functions, only eight functions will be present and discovered by the OneCommand
Manager application after a reboot.
Notes:
RoCE is only available on Windows operating systems.
SR-IOV is not supported with RoCE configurations.
SR-IOV must be disabled on the adapter BIOS when NPar is used. See the
“SRIOVEnable” command for information on disabling SR-IOV on the adapter
BIOS.
For a Linux or VMware operating system, SR-IOV must be enabled on the
system BIOS when NParEP is used. See the documentation that accompanied
your Dell server for more information.
NParEP support is available only on Dell 13G or newer systems.
Only OCe14000-series adapters support ARI.
Supported By
Linux, Solaris, VMware ESXi, and Windows
Syntax
hbacmd SetAdapterPortConfig
or
hbacmd SetAdapterPortConfig
[p2=fcnCfg] [p3=fcnCfg] [pid=ProfileID] [mctype=Type]
[NParEpMode=State]
Parameters
MAC
MAC address of any iSCSI, NIC or NIC+RoCE function on the adapter.
WWPN
WWPN of any FCoE function on the adapter
defaults
Sets the adapter port configuration back its factory default configuration.
No additional parameters should be specified with the “default”
parameter.
p0=fcnCfg
1st port's function(s)
p1=fcnCfg
2nd port's function(s) (required for 2 and 4 port adapters)
p2=fcnCfg
3rd port's function(s) (required for 4 port adapters)
p3=fcnCfg
4th port's function(s) (required for 4 port adapters)