Nic event log, Table a-13 – Dell Emulex Family of Adapters User Manual
Page 705

Emulex Drivers for Windows User Manual
P010077-01A Rev. A
Appendix A. Error and Event Log Information
NIC Error and Event Logs
705
NIC Event Log
Windows Device Manager generates error log codes if any errors occur during the
installation of the NIC driver. Each log contains a Message Id, Severity and Symbolic
Link. The Message Id is unique and tracks the error message (if not displayed).
Table A-13 shows the list of error codes, the severity of the error, the message
displayed, the meaning of the error and recommended resolutions. When reporting an
issue with the adapter to Emulex, check the event log and report any of these entries
that may be present.
Table A-13 NIC Event Log Entries
Message ID
Hexadecimal/
Decimal
Severity
Message
Recommended Resolution
0x80000039
Warning
Firmware does not support GRE
encapsulation. Encapsulation
disabled.
Issue configuring NVRE hardware
offloads. Update firmware on the
OCe14000 adapter.
0x4000003AL
Informational
N/A
N/A
0x0000038L/56
Warning
The device firmware does not
support ETS functionality in SR-IOV
or multichannel mode.
Revert to default mode for ETS
support.
0x00037/55
Warning
This adapter may have an issue
recovering from corrupted use of
SR-IOV. Assigning an SR-IOV device
to a Virtual Machine could leave the
system vulnerable, and lead to
instability. It is strongly
recommended that you assign
SR-IOV devices only to Virtual
Machines that run trusted
workloads, or consider disabling the
use of SR-IOV.
This adapter exposes a vulnerability
to the VM that may allow the VM to
crash the entire physical computer.
This is no different than running a
physical adapter. SR-IOV should only
be used when the VM has a trusted
server administrator.
0x00036/54
Warning
Incompatible optics-
Replace with compatible optics for
card to function.
Replace the incompatible SFP
transceivers with compatible ones
for the card to function correctly.
0x00035/53
Warning
Optics of two types
installed-Remove one optic or
install matching pair of optics.
Remove one SFP transceiver or
install a matching pair of SFP
transceivers.
0x00034/52
Warning
Optics faulted/incorrectly
installed/not installed. Reseat
optics, if issue not resolved,
replace.
Reseat the SFP transceiver. If the
issue is not resolved, replace it.
0x00033/51
Warning
SR-IOV virtualization failed
initialization. Check system BIOS
settings, or disable SR-IOV for the
adapter.
Check system BIOS settings, or
disable SR-IOV for the adapter.
0x00032/50
Warning
The Ethernet link is down due to
PHY over-temperature condition.
Improve cooling for the device.
Improve the cooling conditions for
the device.