Appendix A. Error and Event Log Information

NIC Error and Event Logs

705

NIC Event Log

Windows Device Manager generates error log codes if any errors occur during the

installation of the NIC driver. Each log contains a Message Id, Severity and Symbolic

Link. The Message Id is unique and tracks the error message (if not displayed).

Table A-13 shows the list of error codes, the severity of the error, the message

displayed, the meaning of the error and recommended resolutions. When reporting an

issue with the adapter to Emulex, check the event log and report any of these entries

that may be present.

Table A-13 NIC Event Log Entries

Message ID

Hexadecimal/

Decimal

Severity

Message

Recommended Resolution

0x80000039

Warning

Firmware does not support GRE
encapsulation. Encapsulation
disabled.

Issue configuring NVRE hardware
offloads. Update firmware on the
OCe14000 adapter.

0x4000003AL

Informational

N/A

N/A

0x0000038L/56

Warning

The device firmware does not
support ETS functionality in SR-IOV
or multichannel mode.

Revert to default mode for ETS
support.

0x00037/55

Warning

This adapter may have an issue
recovering from corrupted use of
SR-IOV. Assigning an SR-IOV device
to a Virtual Machine could leave the
system vulnerable, and lead to
instability. It is strongly
recommended that you assign
SR-IOV devices only to Virtual
Machines that run trusted
workloads, or consider disabling the
use of SR-IOV.

This adapter exposes a vulnerability
to the VM that may allow the VM to
crash the entire physical computer.
This is no different than running a
physical adapter. SR-IOV should only
be used when the VM has a trusted
server administrator.

0x00036/54

Warning

Incompatible optics-
Replace with compatible optics for
card to function.

Replace the incompatible SFP
transceivers with compatible ones
for the card to function correctly.

0x00035/53

Warning

Optics of two types
installed-Remove one optic or
install matching pair of optics.

Remove one SFP transceiver or
install a matching pair of SFP
transceivers.

0x00034/52

Warning

Optics faulted/incorrectly
installed/not installed. Reseat
optics, if issue not resolved,
replace.

Reseat the SFP transceiver. If the
issue is not resolved, replace it.

0x00033/51

Warning

SR-IOV virtualization failed
initialization. Check system BIOS
settings, or disable SR-IOV for the
adapter.

Check system BIOS settings, or
disable SR-IOV for the adapter.

0x00032/50

Warning

The Ethernet link is down due to
PHY over-temperature condition.
Improve cooling for the device.

Improve the cooling conditions for
the device.