Dell Emulex Family of Adapters User Manual
Page 902

Emulex Drivers Version 10.2 for Linux User Manual
P010081-01A Rev. A
4. Troubleshooting
Log Messages
902
0384: There is pending active mailbox cmd
The mailbox commands have overlapped. This command should have been added to the mailbox
queue.
Data:
None
Severity: Error
Log:
LOG_MBOX, LOG_SLI
Action:
None required.
0385: rc should have been MBX_BUSY
The completion handler for REG_LOGIN detected the IMMED_UNREG flag and tried to issue the
UNREG_LOGIN command from an interrupt level. The mailbox status should still be busy.
Data:
None
Severity: Error
Log:
LOG_MBOX, LOG_SLI
Action:
None required.
0386: ELS complete with no corresponding cmdiocb: iotag
The completion that the ISR is handling cannot find a tag associated with the IOTAG.
Data:
None
Severity: Warning
Log:
LOG_SLI
Action:
None required.
0387:Failed to allocate an iocbq
Failed to get an IOCBQ from the list of available IOCBQs.
Data:
None
Severity: Error
Log:
LOG_SLI
Action:
None required.
0388:Not a valid WCQE code: x
The event code is invalid. This event will be dropped.
Data:
None
Severity: Error
Log:
LOG_SLI
Action:
Ensure the adapter’s firmware is current.
0391:Error during rpi post operation
The driver was trying to post pages to the firmware to be used to keep target login information and
encountered a failure.
Data:
None
Severity: Error
Log:
LOG_MBOX, LOG_SLI
Action:
Unload and reload the driver.
0393:Error
The driver was trying to post pages to the firmware to keep target login information and
encountered a failure.
Data:
None
Severity: Error
Log:
LOG_MBOX, LOG_SLI
Action:
Unload and reload the driver.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)