Examples Using GetAdatperPortConfig
NPar disabled - 2 Ports, NParEP Mode Disabled
>hbacmd getadapterportconfig 00-00-c9-12-34-56
Number of Ports : 4
Maximum FCoE Functions : 4
Maximum iSCSI Functions : 4
Mixed Mode I/O Allowed : Yes
Concurrent Mode I/O Allowed : Yes
ROCE Functions Allowed : Yes
RebootRequired : No
Active Configuration
Profile ID : 16
MC Type : None
Port Assignments:
Port 1: NIC
Port 2: NIC
Reboot Configuration
Profile ID : 16
MC Type : None
Port Assignments:
Port 1 (p0): NIC
Port 2 (p1): NIC
Note:(pN) labels are the port parameter names to use in the
SetAdapterPortConfig command (e.g. p0=NIC,FCoE p1=NIC,iSCSI).
NPar enabled - 2 Ports, NParEP Mode Enabled on Reboot
>hbacmd getadapterportconfig 00-00-c9-12-34-56
Number of Ports : 4
Maximum FCoE Functions : 4
Maximum iSCSI Functions : 4
Mixed Mode I/O Allowed : Yes
Concurrent Mode I/O Allowed : Yes
ROCE Functions Allowed : Yes
RebootRequired : Yes
Active Configuration
Profile ID : 37
MC Type : NPAR