Dell Emulex Family of Adapters User Manual
Page 243

OneCommand™ Manager Application
P010066-01A Rev. A
8. Managing Adapters and Ports
OCe14000-Series Adapters
243
Priority Membership – The configured priority membership grouping.
Bandwidth % – The configured value of bandwidth for the different Priority
Groups.
Note: PG15 has no bandwidth setting.
Max Configurable PGs – The maximum number of Priority Groups that can
be configured. Bandwidths of all the priority groups must add up to 100%.
Configure DCB Dialog Box Buttons
Defaults – Click to return to the factory settings.
Configuration Rules – Click to display the NIC Priority window that lists the
rules for configuring NIC priorities.
You must observe the following rules when configuring priority groups for
RoCE adapter ports:
1. The RoCE priority must be assigned as a PFC priority too.
2. Only the RoCE priority can be assigned to PG15.
3. The RoCE priority can be assigned to the PG15 as a single priority or any
other PG as the single priority to the PG (i.e. no other priorities can be
assigned to the PG where the RoCE priority is assigned). All other priorities
should be assigned to a single PG.
4. No bandwidth is specified for PG15. The bandwidths for PG0-PG7 must
add up to 100.
OK – Click to apply and save your changes.
Cancel – Click to discard any changes you made.