Dell Emulex Family of Adapters User Manual
Page 886

Emulex Drivers Version 10.2 for Linux User Manual
P010081-01A Rev. A
4. Troubleshooting
Log Messages
886
0233: Nodelist not empty
Driver unloaded or hotplug detected a node still in use.
Data:
None
Severity: Error
Log:
LOG_DISCOVERY
Action:
None required.
0237: Pending Link Event during Discovery: State
Received link event during discovery. Causes discovery restart.
Data: None
Severity: Warning
Log: LOG_DISCOVERY
verbose
Action: None required, unless this issue persists. If persistent, check cabling.
0241: NameServer rsp error
The driver received a NameServer response containing a status error.
Data:
(1) CommandResponse.bits.CmdRsp (2) ReasonCode (3) Explanation (4) fc_flag
Severity: Error
Log:
LOG_DISCOVERY verbose
Action:
Check the fabric configuration. The driver recovers from this and continues with device
discovery.
0246: RegLogin failed
The firmware returned a failure for the specified RegLogin.
Data:
(1) Did (2) mbxStatus (3) hbaState
Severity: Error
Log:
Always
Action:
This message indicates that the firmware could not do RegLogin for the specified DID.
There may be a limitation on how many nodes an HBA can see.
0249: Cannot issue Register Fabric login: Err %d\
Could not issue the fabric reg login, the err value is unique for each possible failure.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
None required.
0251: NameServer login: no memory
Could not allocate memory for the NDLP structure.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
None required.
0252: Cannot issue NameServer login
Could not issue an ELS PLOGI to the NameServer DID.
Data:
None
Severity: Error
Log:
LOG_ELS
Action:
Check the port connection and the switch configuration.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)