Fc adapter information field definitions, Figure 8-1 – Dell Emulex Family of Adapters User Manual
Page 114

OneCommand™ Manager Application
P010066-01A Rev. A
8. Managing Adapters and Ports
FC/FCoE
114
2. Select an FC adapter in the discovery-tree.
Figure 8-1 FC Adapter Information Tab
FC Adapter Information Field Definitions
Model – The complete model name of the adapter.
Serial Number – The manufacturer's serial number for the adapter.
Hardware Version – Displays the JEDEC ID.
Device ID – The default device ID for the selected adapter. (Not supported on
VMware ESXi servers being managed through the CIM interface.)
Adapter Temperature – If the adapter's temperature is not available, “Not
Supported” is displayed. If supported by the adapter, this field displays the
adapter's temperature and one of the following temperature-related status
messages:
Normal: The adapter’s temperature is within normal operational range.
Warning: The adapter’s temperature is beyond normal operational range. If
the temperature continues to increase, the adapter shuts down. You must
determine the cause of the temperature problem and fix it immediately.
Check for system cooling issues. Common causes of system cooling issues
include clogged air filters, inoperable fans and air conditioning problems
that cause high ambient air temperatures.
Exceeds operational range – Adapter stopped: The temperature has reached
critical limit, forcing the adapter to shut down. You must determine the
cause of the temperature problem and fix it before resuming operation.
Check for system cooling issues. Common causes of system cooling issues
include clogged air filters, inoperable fans and air conditioning problems
that cause high ambient air temperatures.