Dell Emulex Family of Adapters User Manual
Page 1060

Emulex Drivers Version 10.2 for VMware ESXi User Manual
P010087-01A Rev. A
4. Troubleshooting
Troubleshooting the FC/FCoE Driver
1060
elx_mes0385: rc should have been MBX_BUSY
DESCRIPTION: The completion handler for REG_LOGIN detected the
IMMED_UNREG flag and tried to issue the unreg_login command from an interrupt
level. The mailbox status should still be busy.
DATA: None
ACTION: None required.
elx_mes0387: Failed to allocate an iocbq
DESCRIPTION: Failed to get an IOCBQ from the list of available IOCBQs.
DATA: None
ACTION: None required.
elx_mes0388: Not a valid WCQE code:
DESCRIPTION: The event code is invalid. This event is dropped.
DATA: None
ACTION: Ensure that the adapter’s firmware is current.
elx_mes0391: Error during rpi post operation
DESCRIPTION: The driver was trying to post pages to the firmware to be used to keep
target login information and encountered a failure.
DATA: None
ACTION: Unload and reload the driver.
elx_mes0393: Error
DESCRIPTION: The driver was trying to post pages to the firmware to keep target
login information and encountered a failure.
DATA: None
ACTION: Unload and reload the driver.
elx_mes0394: Failed to allocate CQ_EVENT entry
DESCRIPTION: The asynchronous event handler was not able to allocate an event
queue entry to which to transfer the asynchronous event.
DATA: None
ACTION: This could be a V-LINK clear from the switch or a fatal error from the
firmware. Perform a dump from the OneCommand Manager application.
elx_mes0395: The mboxq allocation failed
DESCRIPTION: The asynchronous link event handler could not allocate a mailbox
command to issue the READ_LA (read link attention) mailbox command.
DATA: None