Emulex Drivers Version 10.2 for VMware ESXi User Manual

P010087-01A Rev. A

4. Troubleshooting

Troubleshooting the FC/FCoE Driver

1060

elx_mes0385: rc should have been MBX_BUSY

DESCRIPTION: The completion handler for REG_LOGIN detected the

IMMED_UNREG flag and tried to issue the unreg_login command from an interrupt

level. The mailbox status should still be busy.
DATA: None
ACTION: None required.

elx_mes0387: Failed to allocate an iocbq

DESCRIPTION: Failed to get an IOCBQ from the list of available IOCBQs.
DATA: None
ACTION: None required.

elx_mes0388: Not a valid WCQE code:

DESCRIPTION: The event code is invalid. This event is dropped.
DATA: None
ACTION: Ensure that the adapter’s firmware is current.

elx_mes0391: Error during rpi post operation

DESCRIPTION: The driver was trying to post pages to the firmware to be used to keep

target login information and encountered a failure.
DATA: None
ACTION: Unload and reload the driver.

elx_mes0393: Error during rpi post operation

DESCRIPTION: The driver was trying to post pages to the firmware to keep target

login information and encountered a failure.
DATA: None
ACTION: Unload and reload the driver.

elx_mes0394: Failed to allocate CQ_EVENT entry

DESCRIPTION: The asynchronous event handler was not able to allocate an event

queue entry to which to transfer the asynchronous event.
DATA: None
ACTION: This could be a V-LINK clear from the switch or a fatal error from the

firmware. Perform a dump from the OneCommand Manager application.

elx_mes0395: The mboxq allocation failed

DESCRIPTION: The asynchronous link event handler could not allocate a mailbox

command to issue the READ_LA (read link attention) mailbox command.
DATA: None