Dell Emulex Family of Adapters User Manual
Page 893

Emulex Drivers Version 10.2 for Linux User Manual
P010081-01A Rev. A
4. Troubleshooting
Log Messages
893
0302: REG_LOGIN: no buffers
The driver attempted to issue a REG_LOGIN mailbox command to the adapter, but there no buffers
were available.
Data:
(1) Did, (2) flag
Severity: Warning
Log: LOG_MBOX
verbose
Action: This message indicates: (1) Kernel virtual memory is depleted. Check that the system
meets minimum RAM requirements for the Emulex FC adapter. Try closing other
applications to free some memory. (2) A possible driver buffer management issue. If this
issue persists, report the error to Technical Support.
0313: Ring
The RCTL/Type of a received frame did not match any for the configured masks for the specified
ring.
Data: None
Severity: Warning
Log: LOG_SLI
verbose
Action: This error could indicate a software driver, firmware, or hardware issue. Report these
errors to Technical Support.
0303: Ring
The port rsp ring put index is larger than the size of the rsp ring.
Data:
None
Severity: Error
Log:
Always
Action:
This error could indicate a software driver, firmware or hardware issue. Report these
errors to Technical Support.
0304: Stray mailbox interrupt, mbxCommand
Received a mailbox completion interrupt and there are no outstanding mailbox commands.
Data:
None
Severity: Error
Log:
Always
Action:
This error could indicate a hardware or firmware issue. If this issue persists, report the
error to Technical Support.
0306: CONFIG_LINK mbxStatus error
The driver issued a CONFIG_LINK mailbox command to the HBA that failed.
Data:
None
Severity: Error
Log:
Always
Action:
This error could indicate a firmware or hardware issue. Report these errors to Technical
Support.
0310: Mailbox command
A mailbox command was posted to the adapter and did not complete within 30 seconds.
Data:
(1) hba_state (2) sli_flag (3) mbox_active
Severity: Error
Log:
Always
Action:
This error could indicate a software driver or firmware issue. If no I/O is going through
the adapter, reboot the system. If this issue persists, report the error to Technical
Support.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)