Default vlan tagging, Virtual guest tagging, Configuring a static mac for a vf – Dell Emulex Family of Adapters User Manual
Page 1001: Configuring npar (dell only)

Emulex Drivers Version 10.2 for VMware ESXi User Manual
P010087-01A Rev. A
2. Installation
Installing the NIC Driver
1001
Default VLAN Tagging
When default VLAN tagging is configured on a VF, a VLAN ID is automatically added
to and removed from every packet sent and received over the VF.
To configure a default VLAN tag:
1. Power off the VM before proceeding to the next step.
2. Edit the
under /vmfs/volumes/Datastore/
3. Append the following line:
pciPassthru
where
assigned to the VM.
4. Power on the VM.
Virtual Guest Tagging
When VGT is configured, a guest operating system can configure any VLAN ID using
the native VLAN configuration method in the guest operating system.
To enable VGT:
1. Configure the special VLAN ID 4095 using the steps listed in “Default VLAN
2. Use the native method in the guest operating system to configure the required
VLAN ID (for example, vconfig in the Linux guest operating system).
Configuring a Static MAC for a VF
A MAC address is automatically configured by ESXi for each VF. This default MAC
address may be modified using the following steps:
1. Power off the VM before proceeding to the next step.
2. Edit the
under /vmfs/volumes/Datastore/
3. To configure the MAC address “00:50:56:00:00:02” on the first VF assigned to this
VM, append the following lines:
pciPassthru0.MACAddressType = "static"
pciPassthru0.MACAddress = "00:50:56:00:00:02"
4. Power on the VM.
Configuring NPar (Dell Only)
Notes
This section is specific to Dell.
SR-IOV must be disabled on the adapter BIOS when NPar is used. See the
following documentation for information on disabling SR-IOV on the adapter
BIOS: