Dell Emulex Family of Adapters User Manual
Page 1138

Emulex Drivers Version 10.2 for VMware ESXi User Manual
P010087-01A Rev. A
4. Troubleshooting
Troubleshooting the iSCSI Driver
1138
Warning
A connection to the target was lost for
a period exceeding the Extended
Timeout (ETO). The error log entry
immediately following this entry will
indicate the session ID of the target
that lost the connection. There will be
event log entries from the disk
subsystem indicating that the drives
were lost. If any I/Os were in progress,
the system may see I/O errors or
failures.
Check the connection to the target or
the state of the target device. If the
target is made available, any sessions
that existed previously will be
reestablished and the devices will be
available for I/O.
Warning
The be2iscsi driver received a Task
Management Function that is not
supported and rejected this request.
The error log entry immediately
following this entry will indicate the
TMF function code that was rejected.
The operating system version is not
supported.
Warning
The be2iscsi driver received a Task
Management Function Abort request
for an I/O request that is not present
with the driver.
This message may indicate a slow
connection to the target. Check
network connectivity to the target for
any errors.
Error
The be2iscsi driver encountered a
mismatched version of the firmware
running on the board. This error may
be followed by more error codes
0x31840001 or 0x31880001 indicating
that the be2iscsi driver failed to load.
This failure indicates that the driver
version that is running on the system
does not match the version of the
firmware flashed on the board. Fix this
by installing the desired version.
Error
The be2iscsi driver detected a failure
in the hardware during initialization.
This error may be followed by more
error codes 0x31840001 or 0x31880001
indicating that the be2iscsi driver
failed to load.
This failure indicates that the
hardware has not been initialized or is
malfunctioning. This may also indicate
that the firmware is not running
correctly.
Warning
Both Port 0 and Port 1 links were down
for a period exceeding the Link Down
Timeout (LDTO). If the initiator has
connection to the target, there will be
event log entries from the disk
subsystem indicating that the drives
were lost. If any I/Os were in progress,
the system may see I/O errors or
failures.
Check the links to the adapter. If the
link is reestablished, any sessions that
existed previously will be
reestablished and the devices will be
available for I/O.
Warning
Both Port 0 and Port 1 links are down. Check the links to the adapter.
Table 4-7 iSCSI Error Log Code Entries (Continued)
Severity
Message
Recommended Resolution