Listprofiles, Listprofiles”com – Dell Emulex Family of Adapters User Manual
Page 418

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
5. CLI Client Command Descriptions
Profile Management Commands
418
NIC+RoCE
>hbacmd getadapterportconfig 00-00-c9-12-34-56
Number of Ports : 4
Maximum FCoE Functions : 4
Maximum iSCSI Functions : 4
Mixed Mode I/O Allowed : Yes
Concurrent Mode I/O Allowed : Yes
ROCE Functions Allowed : Yes
RebootRequired : No
Active Configuration
Profile ID : 21
MC Type : None
Port Assignments:
Port 0: NIC+RoCE,None,None
Port 1: NIC,None,None
Port 2: NIC+RoCE,None,None
Port 3: NIC,None,None
Reboot Configuration
Profile ID : 21
MC Type : None
Port Assignments:
Port 0 (p0): NIC+RoCE,None,None
Port 1 (p1): NIC,None,None
Port 2 (p2): NIC+RoCE,None,None
Port 3 (p3): NIC,None,None
Note:(pN) labels are the port parameter names to use in the
SetAdapterPortConfig command (e.g. p0=NIC,FCoE p1=NIC,iSCSI).
ListProfiles
This command shows a list of the available profile IDs and their descriptions for an
adapter including the currently active and configured profile IDs. This information
helps to determine the appropriate profile ID to specify to the ChangePersonality and
SetAdapterPortConfig commands required for RoCE and NIC-only configurations. The
specific profiles listed may vary according to the adapter model.
Note: RoCE is only available on Windows operating systems.
Supported By
Linux, Solaris, VMware ESXi, and Windows