4. Troubleshooting
Troubleshooting the FC/FCoE Driver
680
lpfc_mes0703: Issue LUN reset to PathId: x%x, TargetId: x%x, Lun: x%x,
Did: x%x
lpfc_mes0713: Issued Target Reset to PathId:%d, TargetId:%d, Did: x%x
lpfc_mes0714: Issued Bus Reset for PathId:%d
lpfc_mes0716: FCP Read Underrun, expected%d, residual%d
Description
Storport is requesting a reset of the indicated
LUN.
Severity
Warning
Log
LOG_INIT verbose
Action
Review system configuration. Possible side-effect
of cluster operations.
Description
Storport detected that it needs to abort all I/O to
a specific target. This results in login reset to the
target in question.
Severity
Warning
Log
LOG_FCP verbose
Action
Review system configuration. Possible side-effect
of cluster operations.
See Also
lpfc_mes0714
Description
Storport is requesting the driver to reset all
targets on this adapter.
Severity
Warning
Log
LOG_FCP verbose
Action
Review system configuration. Possible side-effect
of cluster operations.
See Also
lpfc_mes0713
Description
FCP device provided less data than was
requested.
Severity
Supplement Information
Log
LOG_FCP verbose
Action
No action needed, informational.
See Also
lpfc_mes0730