beautypg.com

Dell Emulex Family of Adapters User Manual

Page 680

background image

Emulex Drivers for Windows User Manual

P010077-01A Rev. A

4. Troubleshooting

Troubleshooting the FC/FCoE Driver

680

lpfc_mes0703: Issue LUN reset to PathId: x%x, TargetId: x%x, Lun: x%x,
Did: x%x

lpfc_mes0713: Issued Target Reset to PathId:%d, TargetId:%d, Did: x%x

lpfc_mes0714: Issued Bus Reset for PathId:%d

lpfc_mes0716: FCP Read Underrun, expected%d, residual%d

Description

Storport is requesting a reset of the indicated

LUN.

Severity

Warning

Log

LOG_INIT verbose

Action

Review system configuration. Possible side-effect

of cluster operations.

Description

Storport detected that it needs to abort all I/O to

a specific target. This results in login reset to the

target in question.

Severity

Warning

Log

LOG_FCP verbose

Action

Review system configuration. Possible side-effect

of cluster operations.

See Also

lpfc_mes0714

Description

Storport is requesting the driver to reset all

targets on this adapter.

Severity

Warning

Log

LOG_FCP verbose

Action

Review system configuration. Possible side-effect

of cluster operations.

See Also

lpfc_mes0713

Description

FCP device provided less data than was

requested.

Severity

Supplement Information

Log

LOG_FCP verbose

Action

No action needed, informational.

See Also

lpfc_mes0730