Table a-3, 698 command errors – Dell Emulex Family of Adapters User Manual
Page 698

Emulex Drivers for Windows User Manual
P010077-01A Rev. A
Appendix A. Error and Event Log Information
FC/FCoE Error and Event Logs
698
Command Errors
0x6A
Unrecognized ELS command received
0x6F
Received PRLI from un-typed source
0x73
Failed to pend PRLI for authentication
0x77
Failed to allocate Node object
0x7A
REG_VPI failed
0xA3
Command context allocation failure
0xAB
SCSI command error
0xAC
Read check error
0xB0
Node timeout: device removal signaled to Storport
Table A-3 Command Errors
Bits 0 – 7
Interpretation
0x43
Fabric login succeeded
0x46
ELS command failed
0x47
Exhausted retries on ELS command
0x4A
PLOGI accepted
0x56
LOGO accepted
0x59
PRLI accepted
0x63
Fabric name server response
0x6B
ELS RSCN processed
0x71
LOGO received from fabric
0x79
FDISC accepted
0xA2
SCSI address assigned to discovered target
0xA4
Report LUNs error (initial I/O to discovered target)
0xA5
Local error indication on FCP command
0xA8
Data overrun
0xA9
FCP command error
0xAA
SCSI check condition
0xAD
Local reject indication on FCP command
0xAE
Error on SCSI pass-through command
0xAF
Error on Menlo CT command
Table A-2 Malfunction Errors (Continued)
Bits 0 – 7
Interpretation