Managing adapters and ports, Fc and fcoe ports, Viewing fc adapter information – Dell Emulex Family of Adapters User Manual
Page 1196: Fc adapter information field definitions, Managing adapters and ports 6, Fc and fcoe ports 6, Figure 6-1

OneCommand Manager for VMware vCenter Version 10.2 User Manual
P010089-01A Rev. A
6. Managing Adapters and Ports
FC and FCoE Ports
1196
6. Managing Adapters and Ports
The adapter information that is displayed depends upon the type of adapter you select;
LightPulse (FC) or OneConnect.
FC and FCoE Ports
Viewing FC Adapter Information
When you select an FC adapter from the Emulex Device Management tree-view, the
Adapter Information pane contains general attributes associated with the selected FC
adapter.
To view information for an FC adapter:
1. Select a host in the vSphere console tree-view and select the Emulex OneCommand
tab.
2. In the Emulex Device Management tree-view, select an FC adapter. The adapter
Information tab is displayed.
Figure 6-1 FC Adapter Information Tab
FC Adapter Information Field Definitions
Model – The complete model name of the adapter.
Manufacturer – The manufacturer of the adapter.
Serial Number – The manufacturer's serial number for the selected adapter.
Device ID – The default device ID for the selected adapter.
HW Version – For LightPulse adapters, this field shows the JEDEC ID.
Adapter Temperature – If the adapter's temperature is not available, “Not
Supported” is displayed. If supported by the adapter, this field shows the
adapter's temperature and one of the following temperature-related status
messages:
Normal – The adapter’s temperature is within normal operational range.
Exceeded operational range – Critical: The adapter’s temperature is beyond
normal operational range. If the temperature continues to increase, the
adapter shuts down. You must determine the cause of the temperature
problem and fix it immediately. Check for system cooling issues. Common