Dell Emulex Family of Adapters User Manual
Page 913

Emulex Drivers Version 10.2 for Linux User Manual
P010081-01A Rev. A
4. Troubleshooting
Log Messages
913
0495: SLI_FUNCTION_RESET mailbox failed with status
Mailbox command failed.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
Reset the HBA.
0496: Failed allocate slow-path EQ
The event queue for the slow path was not allocated.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
Unload and reload the driver.
0497: Failed allocate fast-path EQ
The event queue for the fast path was not allocated.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
Unload and reload the driver.
0499: Failed allocate fast-path FCP CQ (
The completion queue event for the fast path could not be allocated.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
Unload and reload the driver.:
0500: Failed allocate slow-path mailbox CQ
Failed to allocate slow-path mailbox CQ.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
None required.
0501: Failed allocate slow-path ELS CQ
Failed to allocate slow-path ELS CQ.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
None required.
0503: Failed allocate fast-path FCP
Failed to allocate fast-path FCP.
Data:
None
Severity: Error
Log:
LOG_INIT
Action:
None required.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)