OneCommand Manager Command Line Interface Version 10.2 User Manual

P010067-01A Rev. A

5. CLI Client Command Descriptions

Profile Management Commands

437

----- ----- ----------------- ------ ------

0 NIC 00-00-c9-12-34-56 10 100

1 iSCSI 00-00-c9-12-34-57 40 100

2 NIC 00-00-c9-12-34-58 10 100

3 NIC 00-00-c9-12-34-59 10 100

4 NIC 00-00-c9-12-34-5a 10 100

5 NIC 00-00-c9-12-34-5b 10 100

6 NIC 00-00-c9-12-34-5c 10 100

7 NIC 00-00-c9-12-34-5d 0 100

Configuring Ports When Disabling NPar

When NPar is being disabled, each of the ports can be configured to run with a single

NIC or NIC+RoCE function. Use SetAdapterPortConfig command to configure these

ports. See “SetAdapterPortConfig” on page 419 for more information.
The syntax when disabling NPar is the following:

SetAdapterPortConfig

[p2=NIC|NIC+RoCE] [p3=NIC|NIC+RoCE] [pid=20|21]

where:

MAC : MAC address of one of the NIC functions on the adapter

p0=NIC|NIC+RoCE : Protocol to run on 1st port (NIC or NIC+RoCE)

p1=NIC|NIC+RoCE : Protocol to run on 2nd port (NIC or NIC+RoCE)

p2=NIC|NIC+RoCE : Protocol to run on 3rd port, if available (NIC or

NIC+RoCE)

p3=NIC|NIC+RoCE : Protocol to run on 2nd port, if available (NIC or

NIC+RoCE)

pid=20|21 : Required when setting any port to NIC+ROCE

(NIC+RoCE-1=20, NIC+RoCE-2=21)

Note: When specifying any of the ports to run NIC+RoCE for example, p1=RoCE, the

RoCE Profile ID must be specified. It can be either 20 or 21 depending upon the

preferred protocol.

Examples
Disable NPar - 4 Ports, All NIC

>hbacmd setadapterportconfig 00-00-c9-12-34-56 p0=nic p1=nic p2=nic

p3=nic mctype=none

Successfully changed port configuration. A reboot is required to

complete changes.

>hbacmd getadapterportconfig 00-00-c9-12-34-56

Number of Ports : 4

Maximum FCoE Functions : 4

Maximum iSCSI Functions : 4

Mixed Mode I/O Allowed : Yes