Dell Emulex Family of Adapters User Manual
Page 437

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
5. CLI Client Command Descriptions
Profile Management Commands
437
----- ----- ----------------- ------ ------
0 NIC 00-00-c9-12-34-56 10 100
1 iSCSI 00-00-c9-12-34-57 40 100
2 NIC 00-00-c9-12-34-58 10 100
3 NIC 00-00-c9-12-34-59 10 100
4 NIC 00-00-c9-12-34-5a 10 100
5 NIC 00-00-c9-12-34-5b 10 100
6 NIC 00-00-c9-12-34-5c 10 100
7 NIC 00-00-c9-12-34-5d 0 100
Configuring Ports When Disabling NPar
When NPar is being disabled, each of the ports can be configured to run with a single
NIC or NIC+RoCE function. Use SetAdapterPortConfig command to configure these
ports. See “SetAdapterPortConfig” on page 419 for more information.
The syntax when disabling NPar is the following:
SetAdapterPortConfig
[p2=NIC|NIC+RoCE] [p3=NIC|NIC+RoCE] [pid=20|21]
where:
MAC : MAC address of one of the NIC functions on the adapter
p0=NIC|NIC+RoCE : Protocol to run on 1st port (NIC or NIC+RoCE)
p1=NIC|NIC+RoCE : Protocol to run on 2nd port (NIC or NIC+RoCE)
p2=NIC|NIC+RoCE : Protocol to run on 3rd port, if available (NIC or
NIC+RoCE)
p3=NIC|NIC+RoCE : Protocol to run on 2nd port, if available (NIC or
NIC+RoCE)
pid=20|21 : Required when setting any port to NIC+ROCE
(NIC+RoCE-1=20, NIC+RoCE-2=21)
Note: When specifying any of the ports to run NIC+RoCE for example, p1=RoCE, the
RoCE Profile ID must be specified. It can be either 20 or 21 depending upon the
preferred protocol.
Examples
Disable NPar - 4 Ports, All NIC
>hbacmd setadapterportconfig 00-00-c9-12-34-56 p0=nic p1=nic p2=nic
p3=nic mctype=none
Successfully changed port configuration. A reboot is required to
complete changes.
>hbacmd getadapterportconfig 00-00-c9-12-34-56
Number of Ports : 4
Maximum FCoE Functions : 4
Maximum iSCSI Functions : 4
Mixed Mode I/O Allowed : Yes