Dell Emulex Family of Adapters User Manual
Page 424

OneCommand Manager Command Line Interface Version 10.2 User Manual
P010067-01A Rev. A
5. CLI Client Command Descriptions
Profile Management Commands
424
MCType : None
Port Assignments:
Port 1 (p0): NIC,iSCSI,FCoE
Port 2 (p1): NIC,FCoE,None
Note: (pN)labels are the port parameter names to use in the
SetAdapterPortConfig command (e.g. p0=NIC,FCoE 1=NIC,iSCSI).
RoCE
>hbacmd SetAdapterPortConfig 00-00-c9-12-34-56 p0=nic+roce p1=nic
p2=nic p3=nic+roce pid=21
>hbacmd GetAdapterPortConfig 00-00-c9-12-34-56
Number of Ports : 4
Maximum FCoE Functions : 4
Maximum iSCSI Functions : 4
Mixed Mode I/O Allowed : Yes
Concurrent I/O Mode Allowed : Yes
ROCE Functions Allowed : Yes
RebootRequired : Yes
Active Configuration
Profile ID : 37
MCType : None
Port Assignments:
Port 0: NIC,iSCSI,FCoE
Port 1: NIC,FCoE,None
Port 2: NIC,iSCSI,None
Port 3: NIC,None,None
Reboot Configuration
Profile ID : 21
MCType : None
Port Assignments:
Port 0 (p0): NIC+RoCE,None,None
Port 1 (p1): NIC,None,None
Port 2 (p2): NIC,None,None
Port 3 (p3): NIC+RoCE,None,None
Note: (pN)labels are the port parameter names to use in the
SetAdapterPortConfig command (e.g. p0=NIC,FCoE 1=NIC,iSCSI).