beautypg.com

Dell Emulex Family of Adapters User Manual

Page 1049

background image

Emulex Drivers Version 10.2 for VMware ESXi User Manual

P010087-01A Rev. A

4. Troubleshooting

Troubleshooting the FC/FCoE Driver

1049

elx_mes0271: Illegal State Transition: node event , state
Data:

DESCRIPTION: The current node state does not have a handler for this event.
DATA: (1) nlp_rpi, (2) nlp_flag
ACTION: Verify that all targets are still visible to the SCSI mid-layer.

elx_mes0272: Illegal State Transition: node event , state
Data:

DESCRIPTION: The driver is completing a PLOGI but do not have the rcv_plogi flag

set.
DATA: (1) nlp_rpi, (2) nlp_flag
ACTION: Verify that all targets are still visible to the SCSI mid-layer.

elx_mes0273: Unexpected discovery timeout,vport State

DESCRIPTION: The discovery process has timed out.
DATA: None
ACTION: Ensure that all targets are visible.

elx_mes0282: did: ndlp: pusgmap: refcnt,
ndlp->nlp_DID, (void *)ndlp, lpfc_init.c-ndlp->nlp_usg_map

DESCRIPTION: Driver clean-up has found a node that is still on the node list during

driver unload or PCI hotplug removal.
DATA: None.
ACTION: None required.

elx_mes0283: Failed to allocate mbox cmd memory

DESCRIPTION: Mailbox allocation error.
DATA: None
ACTION: None required.

elx_mes0285: Allocated DMA memory size is less than the
requested DMA memorysize

DESCRIPTION: Memory allocation was truncated.
DATA: None
ACTION: None required.

elx_mes0286: lpfc_nlp_state_cleanup failed to allocate statistical data
buffer

DESCRIPTION: Memory allocation failed for node’s statistical data.
DATA: None