elx_mes0311 Mailbox command
DESCRIPTION: The driver detected an HBA error and can't issue the mailbox.
DATA: (1) sli flags (2) hba flags
ACTION: Software driver error. If this issue persists, report these errors to Emulex
technical support.
elx_mes0312: Ring
then rsp ring
DESCRIPTION: The IOCB command rings put pointer is ahead of the get pointer.
DATA: None
ACTION: None required.
elx_mes0315: Ring
then cmd ring
DESCRIPTION: The port cmd ring get index is greater than the size of cmd ring.
DATA: None
ACTION: This error could indicate a software driver, firmware or hardware issue.
Report these errors to Emulex technical support.
elx_mes0317: iotag
wd0
DESCRIPTION: The IoTag in the completed IOCB is out of range.
DATA: None
ACTION: This error could indicate a software driver, firmware or hardware issue.
Report these errors to Emulex technical support.
elx_mes0319: READ_SPARAM mbxStatus error
DESCRIPTION: The driver issued a READ_SPARAM mbox command to the adapter
that failed.
DATA: None
ACTION: This error could indicate a firmware or hardware issue. Report these errors to
Emulex technical support.
elx_mes0320: CLEAR_LA mbxStatus error
DESCRIPTION: The driver issued a CLEAR_LA mbox command to the adapter that
failed.
DATA: None