P010087-01A Rev. A
4. Troubleshooting
Troubleshooting the FC/FCoE Driver
1119
elx_mes2856: Config Port Security Crypto Error:
pmb->u.mb.un.varCfgPort.sec_err
DESCRIPTION:
DATA: None
ACTION: None required.
elx_mes2858: FLOGI failure Status:
DESCRIPTION: The driver issued a FLOGI, but never received any completion with
the timeout period. The driver is marking the FLOGI as failed and stops discovery.
DATA: None
ACTION: Check your Fabric to ensure it is operating correctly. Contact Emulex
technical support if issues persist.
elx_mes2860: SLI authentication is required for INIT_LINK but has not been
done yet
DESCRIPTION:
DATA: None
ACTION: None required.
elx_mes2862: FCF (
DESCRIPTION: The driver has found an FCF record that matches the properties of the
current FCF record, except for the VLAN ID and Index. The driver will attempt to use
this FCF.
DATA: None
ACTION: None required. The driver is in its FCF discovery phase and is trying to
recover a match to its in-use FCF.
elx_mes2863: New FCF (
DESCRIPTION: The driver has found a new FCF record that matches the properties of
the current FCF record, but the record instance numbers do not match.
DATA: None
ACTION: None required. The driver is in its FCF discovery phase and is trying to
recover a match to its in-use FCF.
elx_mes2877: FCP XRI exchange busy wait time:
DESCRIPTION: An FCP exchange cannot be released - no port completion. Driver is
waiting.
DATA: None
ACTION: Software driver error. If this issue persists, report these errors to Emulex