Dell Emulex Family of Adapters User Manual
Page 1048

Emulex Drivers Version 10.2 for VMware ESXi User Manual
P010087-01A Rev. A
4. Troubleshooting
Troubleshooting the FC/FCoE Driver
1048
ACTION: At least one message (0142 0121 0133 0134 0135) should precede this
message.
elx_mes0262: No NPIV Fabric support
DESCRIPTION: The switch to which the port is connected does not support NPIV.
DATA: None
ACTION: Check the switch configuration.
elx_mes0263: Discovery Mailbox error: state:
DESCRIPTION: Either the driver could not allocate resources or it could not send
sparam_mbox or cfglink_mbox.
DATA: (1) address of sparam_mbox command, (2) address of cfglink_mbox command.
ACTION: Attempt to unload and reload the driver when it is convenient.
elx_mes0264: No NPIV Fabric support
DESCRIPTION: The switch to which the port is connected does not support NPIV.
DATA: None
ACTION: Check the switch configuration.
elx_mes0266: Issue NameServer Req
DESCRIPTION: The driver was not able to send the nameserver CT command.
DATA: (1) VPorts fc_flag, (2) VPorts fc_rscn_id_cnt
ACTION: Check the switch and port configurations.
elx_mes0267: NameServer GFF Rsp
DESCRIPTION: The nameServer GFF CT request failed.
DATA: (1) VPorts fc_flag, (2) VPorts fc_rscn_id_cnt
ACTION: Check the switch and port configurations.
elx_mes0268: NS cmd
DESCRIPTION: The nameServer CT request failed.
DATA: None.
ACTION: Check the switch and port configurations.